Home » Products » Gynaecology » DR. ARABIN® Ring Pessary

DR. ARABIN® Ring Pessary

Indication
Genital prolapse (grade 1-2)
Stress incontinence

Category:

Description

The ring pessary is crafted from high-quality silicone and should be stored between 0°C and 50°C, shielded from UV radiation. To maintain its integrity, avoid exposure to reactive substances, gases, ozone, and mineral oil.

Each model has undergone precise compression testing to ensure a consistent level of manual effort is required to fold the device, regardless of its size.

Application/Intended Purpose

The ring pessary is highly flexible and designed for easy self-insertion and removal by the patient. It is recommended for mild cases of genital prolapse and incontinence, provided the pelvic floor has sufficient strength to support it.

Note

The maximal uninterrupted period of application is 30 days(Class IIa). It is recommended that the patient changes the pessary herself, i.e. she should remove it every evening and insert it in the morning. The patient should be trained about application / change by a healthcare professional.

The product must not be used by other patients. The pessary may be cleaned by running water without using any disinfectant.

Application, monitoring and removal

The instructions are revised according to published studies and post-clinical follow-up.

The most recent version is located in Downloads / Instructions.

 

Description

The ring pessary is crafted from high-quality silicone and should be stored between 0°C and 50°C, shielded from UV radiation. To maintain its integrity, avoid exposure to reactive substances, gases, ozone, and mineral oil.

Each model has undergone precise compression testing to ensure a consistent level of manual effort is required to fold the device, regardless of its size.

Application/Intended Purpose

The ring pessary is highly flexible and designed for easy self-insertion and removal by the patient. It is recommended for mild cases of genital prolapse and incontinence, provided the pelvic floor has sufficient strength to support it.

Note

The maximal uninterrupted period of application is 30 days(Class IIa). It is recommended that the patient changes the pessary herself, i.e. she should remove it every evening and insert it in the morning. The patient should be trained about application / change by a healthcare professional.

The product must not be used by other patients. The pessary may be cleaned by running water without using any disinfectant.

Application, monitoring and removal

The instructions are revised according to published studies and post-clinical follow-up.